Reference Standard Sensor

Reference Standard Sensor   Tempsens offers a wide range of master sensors that are used with an accurate temperature source to evaluate the performance of the process and for testing /Calibration process. Tempsens Master Sensors are available for both Thermocouple & RTD.

Tempsens Reference Standard Sensors are available with accuracy upto 1/10, 1/5, 1/3, 1/2 Din, Class A ,class 1 and special are available with different sheath materials.

Reference Standard Sensor    
 
Benefits of Tempsens Reference Sensors:
   
 
  • Very high accuracy and stabilization
  • Manufactured and tested under strict quality control standards
  • Furnished with NABL Accredited Calibration certificate
  • Cost effective solution
  •  
     
    SSPRT 660C with fixed point calibration   K/N Type Thermocouple
    SSPRT  660C with fixed point calibration - P100   Accuracy : 0.3C   K/N Type Thermocouple   Accuracy : Special, Class 1
    Calibration : Fixed Point as per ITS - 90   Calibration : ANSI MC96.1, ASTM E220/ BIS 7358
    Sheath Material : SS316/ Inconel / Quartz   Sheath Material : Inconel 600
     
    R/S Type Thermocouple   Cold Junction Probe for Thermocouple
    SSPRT  660C with fixed point calibration - P100   Accuracy : 1/5, 1/3, 1/2 DIN, Class A   K/N Type Thermocouple   Accuracy : K, J, N, R, S, T (Duplex)
    Calibration : ANSI MC96.1, ASTM E220
    /BIS 7358
      Calibration : Copper
    Sheath Material : KER 710 (C-799)   Sheath Material : M/F Comp. Connector
    Dual Probe Possible in one Housing
     
    PT 100    
    SSPRT  660C with fixed point calibration - P100   Accuracy : 1/5, 1/3, 1/2 DIN, Class A            
    Calibration : DIN, IEC751/BIS 2848        
    Sheath Material : SS316/Inconel        
     
     